www.telecom.fr

 
MATERIELS OPERATEURS TELECOM ET INSTALLATEURS : FIBRE OPTIQUE - TELECOM ET RESEAUX - MOTOROLA - PABX - ELECTRICTE HT....


MULHOUSE FRANCE
 

 
 
CABLE OPTIQUE

DISTRIBUTION

 

SLT-NMA-SJ
SLT-NMA-SJ-P
MLT-NMA-SJ (A-DF(ZN)B2Y)
MLT-NMA-SJ-DRY (A-DQ(ZN)B2Y)
MLT-NMA-SJ-P
MLT-NMA-DJ–ADSS(A-DF(ZN)2YB2Y)
MLT-NMA-SJ-C
MLT-SA-SJ-C
J-V2H nx1 LSZH
A-V2H(SR)2Y nx1
J-VH 1x1 LSZH
J-VH 2x1 LSZH

SYMBOLS DESCRIPTION

SLT

SINGLE LOOSE TUBE

MLT

MULTI LOOSE TUBES CABLE

SA

CORRUGATED STEEL TAPE

NMA

NON METALLIC STRENGHT MEMBER

DA

DOUBLE ARMOR - TWO LEYERS OF GALVANIZED STEEL TAPE

SJ

SINGLE JACKET

DJ

DOUBLE JACKET

-A

AERIAL CABLE

-P

FIBER OPTIC + POWER HYBRID CABLE

LSZH

LOW SMOKE ZERO HALOGEN SHEATH

ADSS

ALL DIELECTRIC SELF SUPPORTIGN CABLE

-T.T.

TURKISH TELECOM STANDARTS

DIN VDE 0888

OPTICAL FIBER CABLES STANDART

A-

OUTDOOR CABLE

B

ARMORING

(BN)

GLASS-YARN - NON METALIC ARMORING FOR RODENT PROTECTION

D

LOOSE BUFFER TUBE, FILLED

E

SINGLE MODE FIBER

F

FILLING COMPOUND IN THE CABLE CORE

G

MULTI MODE FIBER

J-

INDOOR CABLE

(L)

LAMINATED ALUMINUM SHEATH

Q

(DRY SWELLABLE METARIAL IN THE CABLE CORE (DRY CORE)

(SR)

ARMORING BY LAMINATED, CORRUGATED, LONGITUDINAL, OVERLAPPED STEEL TAPE

Y

POLYVINYL CHLORIDE FACKET

2Y

POLYETHYLENE JACKET

(ZN)

NON-METALIC ANTI-BUCKLING ANG STRENGHT MEMBERS

 

CABLE TYPE : SLT-NMA-SJ
APPLICATION : - Light weight structure enables easy and fast installation
- Non Metallic / All dielectric structure prevents electromagnetic interference
- Rodent Protection and waterproof
- Preferred for LAN, WAN applications for structural cabling and premise networks
- Optional LSZH sheath enables usage as Indoor cable as well as Outdoor
CONSTRUCTION : 1.Outer PE Sheath ( Optional LSZH sheath)
2.E-Glass yarn
3.Loose Tube(PBT)
4.Water Resistive Tube filling Compound
5.Optical fibers
6.Ripcord

Optik Fiber Type SM : 652-B, G 652-D, G 655 - MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3
Core Count 2 to 12
Cabe Weight (kg/km) 55
Outer Diameter (mm) 7
Tensile Strength (N) (IEC 794-1-E1) 1200 to 2500
Crush Strength (N/10 cm) (IEC 794-1-E3) 1500
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11) 15xo static &20xo dynamic where o is cable outside diameter in mm
Temperature Range (°C) (IEC 794-1-F -1) Operation -40 to + 70 Installation -30 to + 60

CABLE TYPE : SLT-NMA-SJ-P
APPLICATION : - Light weight structure enables easy and fast installation
- Permits Video, Data and Power Signal transfer on the same cable for CCTV and other applications.
- Used in Signaling Systems (Fire Alarm Systems and etc.)
- Rodent proof and waterproof
- Preferred for LAN, WAN applications for structural cabling and premise networks where the data and power transfer is needed to be managed and controlled from a Data Center.
- Optional LSZH sheath enables to be used as indoor cable as well as Outdoor
CONSTRUCTION : 1.Outer PE Sheath (Optional LSZH sheath)
2.Non metallic Strength Member: Glass Yarn
3.Tube
4.Water Resistive Tube Filling Compound
5.Optical fibers
6.Ripcord
7.Power Cable (2X1.5mm2, 3x1.5 mm2, 2x2.5mm2, 3x2.5mm2)
8.Web

Optik Fiber Type SM : 652-B, G 652-D, G 655- MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3
Core Count 2 to 12
Cable Weight (kg/km) Aprx.130
Outer Diameter (mm) 7.5x15
Tensile Strength (N) (IEC 794-1-E1) 1200
Crush Strength (N/10 cm) (IEC 794-1-E3) 1500
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11) 15xo static &20xo dynamic where o is cable outside diameter in mm
Temperature Range (°C) (IEC 794-1-F -1)

 

Operation -40 to + 70 Installation -30 to + 60

CABLE TYPE : MLT-NMA-SJ (A-DF(ZN)B2Y)
APPLICATION : - Light weight structure enables easy and fast installation
- Possibility of usage as indoor cable as well as Outdoor due to light structure
- Non Metallic Construction / All dielectric structure prevents electromagnetic interference and enables application in power lines side by side with Energy Cables
- Waterproof
- Rodent protection - provided by adequate amount of E glass yarn
- Suitable to be installed with blowing / ploughing method
-Optional LSZH Sheath
CONSTRUCTION : 1.Outer PE Sheath (Optional LSZH Sheath)
2.Non metallic Strength element (Glass Yarn or Aramid Yarn )
3.Core Wrapping(s)
4.PBT Tube.
5.Core filling Compound
6.Optical fibres
7.Water Resistive Tube filling Compound.
8.Non Metallic Central Strength Member
9.Ripcord

Optik Fiber Type SM : 652-B, G 652-D, G 655 MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3>
Tensile Strength (N) (IEC 794-1-E1) 1200 (Min.) to 6000>
Crush Strength (N/10 cm) (IEC 794-1-E3) 3000>
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11) 15xo static &20xo dynamic where o is cable outside diameter in mm>
Temperature Range (°C) (IEC 794-1-F -1)

 

Operation -40 to + 70 Installation -30 to + 60>

 

Fiber Count

Buffer Count Filler Count Cable Diameter Aprx Cable Weight (Kg/Km)

4

1

5

12

100

6

1

5

12

100

8

1 (2)

5 (4)

12

100

10

5

1

12

100

12

1 (3,2)

5 (3,4)

12

100

16

4 (2)

2 (4)

12

100

24

6 (2,4)

0 (4,2)

12

110

36

6 (3)

0 (3)

12

110

48

6 (4)

0 (2)

13

120

60

5

1

13

130

72

6

0

13

130

96

8

0

15

160

144

12

0

20

260

192

16

0

23

290

CABLE TYPE : MLT-NMA-SJ-DRY (A-DQ(ZN)B2Y)
APPLICATION : - Light weight structure enables easy and fast installation
- Possibility of usage as indoor cable as well as Outdoor due to light structure
- Non Metallic Construction / All dielectric structure prevents electromagnetic interference and enables application in power lines side by side with Energy Cables
- Waterproof
- Rodent protection - provided by adequate amount of glass yarn
- Suitable to be installed with blowing / ploughing method
-Optional LSZH Sheath
CONSTRUCTION : 1.Outer PE Sheath (Optional LSZH Sheath)
2.Non metallic Strength element (Glass Yarn or Aramid yarn)
3.Water Swelling Tape
4.PBT Tube.
5.Water Swelling Yarn
6.Optical fibres
7.Water Resistive Tube filling Compound.
8.Non Metallic Central Strength Member (FRP)
9.Ripcord

Optik Fiber Type SM : 652-B, G 652-D, G 655 MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3
Tensile Strength (N) (IEC 794-1-E1) 1200 to 6000
Crush Strength (N/10 cm) (IEC 794-1-E3)

 

3000
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11) 15xo static &20xo dynamic where o is cable outside diameter in mm
Temperature Range (°C) (IEC 794-1-F -1)

 

Operation -40 to + 70 Installation -30 to + 60

 

Fiber Count

Buffer Count

Filler Count

Cable Diameter Aprx

Cable Weight (Kg/Km)

4

1

5

12

100

6

1

5

12

100

8

1

5

12

100

12

1

5

12

110

16

2

4

12

110

24

2

2

13

120

36

3

3

13

120

48

4

2

13

120

60

5

1

13

130

72

6

0

13

130

96

8

0

15

160

144

12

0

20

260

CABLE TYPE : MLT-NMA-SJ-P
APPLICATION : - Light weight structure enables easy and fast installation
- Permits Video, Data and Power Signal transfer on the same cable for CCTV and other applications.
- Used in Signaling Systems (Fire Alarm Systems and etc.)
- Rodent Protection and waterproof
- Preferred for LAN, WAN applications for structural cabling and premise networks where the data and power transfer is needed to be managed and controlled from a Data Center.
- Optional LSZH sheath enables to be used as indoor cable as well as Outdoor
CONSTRUCTION : 1.Outer PE Sheath ( Optional LSZH sheath )
2.Non metallic Strength element (Glass Yarn)
3.Core Wrapping(s)
4.PBT Tube.
5.Core filling Compound
6.Optical fibres
7.Water Resistive Tube filling Compound.
8.Non Metallic Central Strength Member
9.Ripcord
10.Power Cable

Optik Fiber Type SM : 652-B, G 652-D, G 655 MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3
Tensile Strength (N) (IEC 794-1-E1) 1500 to 2500
Crush Strength (N/10 cm) (IEC 794-1-E3) 3000
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11) 15xo static &20xo dynamic where o is cable outside diameter in mm
Temperature Range (°C) (IEC 794-1-F -1) Operation -40 to + 70 Installation -30 to + 60

 

Fiber Count

Buffer Count

Filler Count

Cable Diameter Aprx

Cable Weight (Kg/Km)

4

1

5

12X20

160

6

1

5

12X20

160

8

2

4

12X20

160

10

5

1

12X20

160

12

3

3

12X20

160

16

4

4

12X20

160

24

6

0

12X20

170

36

6

0

12X20

170

48

6

0

13X22

180

60

5

1

13X22

190

72

6

0

13X22

190

96

8

0

15X25

220

144

12

0

20X28

320

CABLE TYPE : MLT-NMA-DJ–ADSS(A-DF(ZN)2YB2Y)
APPLICATION : - Aerial Cable type without Steel Messenger Wire
-Aerial installation between the poles with the help of special installation /suspension equipment.
-All dielectric construction enables application in power lines side by side with Energy Cables
-Very Light and easy to install
- Special High Density Black PE provides excellent resistance during installation and protection against external effects like tough weather conditions and UV Ray during operation.
- Generally preferred as Aerial backbone cable for Wide Area Telecom Networks
CONSTRUCTION : 1.Outer Black special HDPE Sheath.
2.High modulus Aramid Yarns
3.Optional Inner PE Sheath.
4.Core Wrapping(s)
5.PBT tube
6.Core filling Compound.
7.Optical fibers
8.Water Resistive Tube filling Compound
9.Non Metallic Central Strength Member
10.Ripcord

 
Optik Fiber Type SM : 652-B, G 652-D, G 655 MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3
Tensile Strength (N) (IEC 794-1-E1) 2700 (Min.) to 15000
Crush Strength (N/10 cm) (IEC 794-1-E3)

 

4000
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11) 15xo static &20xo dynamic where o is cable outside diameter in mm
Temperature Range (°C) (IEC 794-1-F -1)

 

Operation -40 to + 70 Installation -30 to + 60

 

Fiber Count

Buffer Count Filler Count Inner and outer sheath thickness Cable Diameter Aprx Cable Weight (Kg/Km)

4

1

5

1.1/1.6

14

140

6

1

5

1.1/1.6

14

140

8

2

4

1.1/1.6

14

140

12

1(3)

5 (3)

1.1/1.6

16

150

24

2

4

1.1/1.6

16

150

36

3

3

1.1/1.6

16

150

48

4

2

1.1/1.6

16

160

60

5

1

1.1/1.6

16

180

72

6

-

1.1/1.6

16

180

Sag and Tension Parameter

Installation Parameter Span (m) Sag % Tension N LIGHT Sag % Tension N MEDIUM Sag % Tension N HEAVY Sag % Tension N

30

1.0

445

1.2

1000

2.3

1300

3.0

1960

45

1.0

665

1.3

1390

2.5

1780

3.3.3.6

2640

60

1.0

880

1.4

1740

2.7

2230

3.9

3265

75

1.0

1110

1.4

2100

2.8

2650

4.1

3815

90

1.0

1130

1.5

2400

3.0

3030

-

4345

110

1.0

1570

1.5

2720

3.1

3400

-

-

120

1.0

1790

1.6

3050

3.2

3785

-

-

140

1.0

2050

1.6

3350

3.3

4125

-

-

150

1.0

2230

1.6

3650

3.3

4455

-

-

170

1.0

2500

1.7

3950

-

-

-

-

180

1.0

2700

1.7

4250

-

-

-

 

CABLE TYPE : MLT-NMA-SJ-C
APPLICATION : •Light weight structure enabls easy and fast installation.•Permits Video, Data and Power Signal transfer on the same cable for CCTV and other applications.•Used in Signaling systems (fire Alarm Sysyem and etc.)•Rodent Protection and waterproof.•Preferred for LAN, WAN applications for structural cabling and premise networks where the data and power transfer is needed to be managed and controlled from a Data Center.•Optional LSZH sheath enables to be used as indoor cable as well as Outdoor.
CONSTRUCTION : 1. PE Outer Sheath 2. Water Resistant Glass Yarn 3. Water Swelling Tape 4. Central Strength Member 5. Dry Core 6. Buffer Material (PBT) 7. Thixotrophic Jelly 8. Up to 12 Fibers per Tube & 72 Fibers per Cable 9. Dummy Buffer (Filler) 10. Energy Cable x 2

 

1. Optic Fibre Type

SM : 652-B, G 652-D, G 655

MM : 62.5/125 OM1,50/125 OM2, 50/125 OM3

2. Tensile Strenght (N) (IEC 794-1-E1)

1200 to 6000

3. Crush Strenght (N/10 cm) (IEC 794-1-E3)

3000

4. Min Permissible Bending Radius (mm) (IEC 794-1-E 11)

15xo Static and 20 xo Dynamic

where o iş cable outside diameter in mm

5. Temperature Range (°C) (IEC 794-1-F-1)

Operation -40 to +70 Installation -30 to +60

 

 

Fiber Count

 

(Buffer Count)

 

Filler Count

 

POWER

Cable Diameter Aprx

Cable Weight

(Kg/Km)

4

1

3

2X1.5(mm2 )

11

125

6

1

3

2X1.5(mm2 )

11

125

8

1

3

2X1.5(mm2 )

11

125

12

2

2

2X1.5(mm2 )

11

125

16

2

2

2X1.5(mm2 )

11

125

18

3

1

2X1.5(mm2 )

11

125

24

3

1

2X1.5(mm2 )

11

125

36

3

1

2X1.5(mm2 )

12

140

48

4

0

2X1.5(mm2 )

12

140

60

5

1

2X1.5(mm2 )

13

170

72

6

0

2X1.5(mm2 )

13

170

4

1

3

2X2.5(mm2 )

12

155

6

1

3

2X2.5(mm2 )

12

155

8

1

3

2X2.5(mm2 )

12

155

12

2

2

2X2.5(mm2 )

12

155

16

2

2

2X2.5(mm2 )

12

155

18

3

1

2X2.5(mm2 )

12

155

24

3

1

2X2.5(mm2 )

12

155

36

3

1

2X2.5(mm2 )

12

155

48

4

0

2X2.5(mm2 )

12

155

60

5

1

2X2.5(mm2 )

13

185

72

6

0

2X2.5(mm2 )

13

185

CABLE TYPE : MLT-SA-SJ-C
APPLICATION : •Light weight structure enabls easy and fast installation.•Permits Video, Data and Power Signal transfer on the same cable for CCTV and other applications.•Used in Signaling systems (fire Alarm Sysyem and etc.)•Rodent Protection and waterproof.•Preferred for LAN, WAN applications for structural cabling and premise networks where the data and power transfer is needed to be managed and controlled from a Data Center.•Optional LSZH sheath enables to be used as indoor cable as well as Outdoor.
CONSTRUCTION : 1. PE Outer Sheath 2. Corrugated Steel Tape 3. Water Resistant Glass Yarn 4. Water Swelling Tape 5. Central Strength Member 6. Dry Core 7. Buffer Material (PBT) 8. Thixotrophic Jelly 9. Up to 12 Fibers per Tube & 72 Fibers per Cable 10. Dummy Tube (Filler) 11. Energy Cable x 2

1. Optic Fibre Type

SM :652-B, G 652-D, G 655

MM : 62.5/125 OM1,50/125 OM2, 50/125 OM3

2. Tensile Strength (N) (IEC 794-1-E1)

(Min)1000 to (Max) 5000

3. crush Strength (N/10 cm) (IEC 794-1-E3)

4000

4. Min. Permissible bending Radius (mm) (IEC 794-1-E 11)

15xo Static and 20xo Dynamic Where o is cable outside diameter mm

5. Temperature Range (°C) (IEC 794-1-F-1)

Operation -40 to +70 Installation -30 ~ to +60

 

 

Fiber Count

 

(Buffer Count)

 

Filler Count

 

POWER

Cable Diameter Aprx

Cable Weight

(Kg/Km)

4

1

3

2X1.5(mm2 )

12

175

6

1

3

2X1.5(mm2 )

12

175

8

1

3

2X1.5(mm2 )

12

175

12

2

2

2X1.5(mm2 )

12

175

16

2

2

2X1.5(mm2 )

12

175

18

3

1

2X1.5(mm2 )

12

175

24

3

1

2X1.5(mm2 )

12

175

36

3

1

2X1.5(mm2 )

13

190

48

4

0

2X1.5(mm2 )

13

190

60

5

1

2X1.5(mm2 )

14

210

72

6

0

2X1.5(mm2 )

14

210

4

1

3

2X2.5(mm2 )

13

200

6

1

3

2X2.5(mm2 )

13

200

8

1

3

2X2.5(mm2 )

13

200

12

2

2

2X2.5(mm2 )

13

200

16

2

2

2X2.5(mm2 )

13

200

18

3

1

2X2.5(mm2 )

13

200

24

3

1

2X2.5(mm2 )

13

200

36

3

1

2X2.5(mm2 )

14

200

48

4

0

2X2.5(mm2 )

14

200

60

5

1

2X2.5(mm2 )

15

225

72

6

0

2X2.5(mm2 )

15

225

CABLE TYPE : J-V2H nx1 LSZH
APPLICATION : Indoor and duct installations; Halogen Free Flame Retardant / Flame Retardant Non-Corrosive / Low Smoke Zero Halogen design; All dielectric non-metallic construction, hence no ground loop problems; Ready for direct connectorization in field; Suitable for backbone and horizontal sub systems such as FTTH and FTTD
CONSTRUCTION : 1.Optical fiber 2. Tight buffered fibre of 900 m diameter (Easy to strip) 3. Non-metallic strenght members (Aramide or glass yarn) 4. Flame Retardant Non-Corrosive / Low Smoke Zero Halogen Outer Jacket

 
Number of Fibers (n) 2 - 12
Optic Fiber Type ITU-T G.651 (MM), ITU-T G.652 (SM), ITU-T G.655 & G.656 (NZDS Fiber)
Outer Diameter (mm) 4 [mm] to 7.5 [mm]
Weight (kg/km) 35, 60
Tensile Strength (N) 400 to 2000
Crush Resistance (N) 1000
Minimum Bending Radius (mm) 15 x D (Where D, overall diameter of cable)
Operating Temperature (°C) -30°C to +70°C
Standard Cable Color Multi-mode 50/125 - 62.5/125 Single-mode Orange Yellow (Other colors are available upon request)
Standard Reel Length 1000-2000 m
Standard Cable Marking SIPTEL Cable

CABLE TYPE : A-V2H(SR)2Y nx1
APPLICATION : Outdoor and duct installations; Ready for direct connectorization in field; Suitable for backbone and horizontal sub systems such as FTTH and FTTD
CONSTRUCTION : 1.Optical fiber
2.Tight buffered fibre of 900 m diameter (Easy to strip)
3.Non-metallic strenght members (Aramide or glass yarn)
4.Flame Retardant Non-Corrosive / Low Smoke Zero Halogen Inner Jacket
5.Corrugated Steel Tape armored.
6.Outer Black PE Sheath.

 

Number of Fibers (n) 2 - 12
Optic Fiber Type ITU-T G.651 (MM), ITU-T G.652 (SM), ITU-T G.655 & G.656 (NZDS Fiber)
Outer Diameter (mm) 10 [mm] to 12 [mm]
Weight (kg/km) 110, 140
Tensile Strength (N) 1200 to 2000
Crush Resistance (N) 2000
Minimum Bending Radius (mm) 20 x D (Where D, overall diameter of cable)
Operating Temperature (°C) -30°C to +70°C
Standard Cable Color Black (Other colors are available upon request)
Standard Reel Length 1000-2000 m
Standard Cable Marking SIPTEL Cable

CABLE TYPE : J-VH 1x1 LSZH
APPLICATION : Indoor interconnect and Patch-cord installations. All dielectric non-metallic construction, hence no ground loop problems
CONSTRUCTION : 1.Optical fiber
2.Tight buffered fibre of 900 m diameter (Easy to strip)
3.Non-metallic strenght members (Aramide or glass yarn)
4.Flame Retardant Non-Corrosive / Low Smoke Zero Halogen Outer Jacket

Number of Fibers (n) 1
Optic Fiber Type ITU-T G.651 (MM), ITU-T G.652 (SM), ITU-T G.655 & G.656 (NZDS Fiber)
Outer Diameter (mm) 1.8 [mm] or 2.8 [mm]
Weight (kg/km) 5,10
Minimum Bending Radius (mm) 25
Tensile Strength (N) 150, 200
Crush Resistance (N) 300
Operating Temperature (°C) -30°C to +70°C
Standard Cable Color Multi-mode 50/125 - 62.5/125 Single-mode Blue Orange Yellow (Other colors are available upon request)
Standard Cable Marking SIPTEL Cable

CABLE TYPE : J-VH 2x1 LSZH
APPLICATION : Indoor interconnect and Patch-cord installations. All dielectric non-metallic construction, hence no ground loop problems
CONSTRUCTION : 1.Optical fiber
2.Tight buffered fibre of 900 m diameter (Easy to strip)
3.Non-metallic strenght members (Aramide or glass yarn)
4.Flame Retardant Non-Corrosive / Low Smoke Zero Halogen Outer Jacket

Number of Fibers (n) 2
Optic Fiber Type ITU-T G.651 (MM), ITU-T G.652 (SM), ITU-T G.655 & G.656 (NZDS Fiber)
Outer Diameter (mm) 1.8 x3.6 / 2.8 x 5.6
Weight (kg/km) 14,20
Minimum Bending Radius (mm) 25
Tensile Strength (N) 300
Crush Resistance (N) 400
Operating Temperature (°C) -30°C to +70°C
Standard Cable Color Multi-mode 50/125 - 62.5/125 Single-mode Blue Orange Yellow (Other colors are available upon request)
Standard Cable Marking SIPTEL Cable

 

© 2011 SIPTEL™ Tous droits réservés

Accueil - Groupe - Mentions légales - Confidentialité - Recrutement - Références - Contact