www.telecom.fr

 
MATERIELS OPERATEURS TELECOM ET INSTALLATEURS : FIBRE OPTIQUE - TELECOM ET RESEAUX - MOTOROLA - PABX - ELECTRICTE HT....


MULHOUSE FRANCE
 

 
 
CABLE OPTIQUE LOOSE TUBE

SOUTERRAIN

 

MLT-SA-SJ (A-DF(ZN)(SR)2Y)
MLT-DA-DJ
MLT-SA-DJ (A-DF(ZN)2Y(SR)2Y
MLT-SA-DJ-T.T.
MLT-NMA-DJ / (A-DF(ZN)2YB2Y)


 

SYMBOLS DESCRIPTION

SLT

SINGLE LOOSE TUBE

MLT

MULTI LOOSE TUBES CABLE

SA

CORRUGATED STEEL TAPE

NMA

NON METALLIC STRENGHT MEMBER

DA

DOUBLE ARMOR - TWO LEYERS OF GALVANIZED STEEL TAPE

SJ

SINGLE JACKET

DJ

DOUBLE JACKET

-A

AERIAL CABLE

-P

FIBER OPTIC + POWER HYBRID CABLE

LSZH

LOW SMOKE ZERO HALOGEN SHEATH

ADSS

ALL DIELECTRIC SELF SUPPORTIGN CABLE

-T.T.

TURKISH TELECOM STANDARTS

DIN VDE 0888

OPTICAL FIBER CABLES STANDART

A-

OUTDOOR CABLE

B

ARMORING

(BN)

GLASS-YARN - NON METALIC ARMORING FOR RODENT PROTECTION

D

LOOSE BUFFER TUBE, FILLED

E

SINGLE MODE FIBER

F

FILLING COMPOUND IN THE CABLE CORE

G

MULTI MODE FIBER

J-

INDOOR CABLE

(L)

LAMINATED ALUMINUM SHEATH

Q

(DRY SWELLABLE METARIAL IN THE CABLE CORE (DRY CORE)

(SR)

ARMORING BY LAMINATED, CORRUGATED, LONGITUDINAL, OVERLAPPED STEEL TAPE

Y

POLYVINYL CHLORIDE FACKET

2Y

POLYETHYLENE JACKET

(ZN)

NON-METALIC ANTI-BUCKLING ANG STRENGHT MEMBERS

 

CABLE TYPE : MLT-SA-SJ (A-DF(ZN)(SR)2Y)
APPLICATION : - Light weight but heavy duty direct burial / duct usage.
- Single sheath enables easy and fast installations.
- Suitable to be installed and used in harsh environments under heavy weather conditions
- Rodent Protection and waterproof
- Application both as backbone cable for WAN Telecommunication Systems and as data lines for LAN /Structure Cabling
CONSTRUCTION : 1.Outer PE Sheath. ( Optional LSZH sheath )
2.Corrugated Steel Tape Armored .
3. Non metallic Strength Element (Glass Yarn or Aramid Yarn)
4.Core Wrapping(s)
5.Core filling Compound.
6.PBT Tube
7.Water Resistive Tube filling Compound.
8.Optical fibers
9.Non Metallic Central Strength Member(FRP)
10.Ripcord

Optik Fiber Type SM : 652-B, G 652-D, G 655 MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3
Tensile Strength (N) (IEC 794-1-E1) 1500 (Min.) to 5000
Crush Strength (N/10 cm) (IEC 794-1-E3)

 

4000
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11) 15xo static &20xo dynamic where o is cable outside diameter in mm
Temperature Range (°C) (IEC 794-1-F -1)

 

Operation -40 to + 70 Installation -30 to + 60

 

Fiber Count

Buffer Count Filler Count Cable Diameter Aprx Cable Weight (Kg/Km)

4

1

5

13

150

6

1

5

13

150

8

1 (2)

5 (4)

13

150

10

5

1

13

150

12

1 (3,2)

5 (3,4)

13

150

16

4 (2)

2 (4)

13

150

24

6 (2,4)

0 (4,2)

13

160

36

6 (3)

0 (3)

14

160

48

6 (4)

0 (2)

14

160

60

5

1

14

170

72

6

0

14

170

96

8

0

16

210

144

12

0

19

330

192

16

0

22

560

CABLE TYPE : MLT-DA-DJ
APPLICATION : - Heavy duty cable for direct burial / duct usage.
- Suitable to be installed and used in harsh environments under heavy weather conditions
- Galvanized Steel Armor and Second Jacket provides protection against Rodents, moisture and all external effects.
- Aluminum foil provides extra protection against moisture
- Suitable to be used for all type of underground applications
- Rodent Protection and waterproof
- To be used as backbone cable for WAN telecommunication systems
- Two layers of galvanized steel tapes helically overlapped around the inner jacket to improve the mechanical strength of the cable
CONSTRUCTION : 1.Outer PE Sheath.
2.Crepe Paper
3.Helically Applied Double layer of Galvanized Steel Tape by overlapping method
4.Crepe Paper
5.Inner PE Sheath
6.Aluminum Foil
7.Aramid Yarn for tensile strength
8.Core Wrapping(s)
9.Core filling Compound.
10.Ripcord
11.PBT Tube
12.Water Resistive Tube filling Compound.
13.Optical fibers
14.Non Metallic Central Strength Member

Optik Fiber Tipi SM : 652-B, G 652-D, G 655 MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3
Tensile Strength (N) (IEC 794-1-E1) 3000 (Min.) to 10000
Crush Strength (N/10 cm) (IEC 794-1-E3)

 

6000
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11) 20xo static &20xo dynamic where o is cable outside diameter in mm
Temperature Range (°C) (IEC 794-1-F -1)

 

 

Operation -40 to + 70 Installation -30 to + 60

 

Fiber Count

Buffer Count Filler Count Inner and outer sheath thickness Cable Diameter Aprx Cable Weight (Kg/Km)

4

1 5 1.1/2 17 370

6

1 5 1.1/2 17 370

8

2 4 1.1/2 17 370

10

5 1 1.1/2 17 370

12

3 3 1.1/2 17 370

24

6 - 1.1/2 17 370

36

6 - 1.1/2 18,5 440

48

6 - 1.1/2 18,5 440

72

6 - 1.1/2 19,5 480

96

8 - 1.1/2 21 580

144

12 - 1.1/2 25 810

CABLE TYPE : MLT-SA-DJ (A-DF(ZN)2Y(SR)2Y
APPLICATION : - Heavy duty cable for direct burial / duct usage.
- Suitable to be installed and used in harsh environments under heavy weather conditions
- Corrugated Steel Armor and Second Jacket provides extra protection against external effects
- To be used as backbone cable for MAN, WAN, LAN, applications and for GSM, CATV, SMATV networks
- Rodent protection and waterproof
- Possibility of installation with blowing / plough technique into PE pipes or applied directly underground
CONSTRUCTION : 1.Outer PE Sheath.
2.Corrugated Steel Tape Armored.
3.Inner PE Sheath
4.Aramid yarn for tensile strength (or Glass Yarn)
5.Core Wrapping(s)
6.Core filling Compound.
7.Ripcord
8.PBT Tube
9.Water Resistive Tube filling Compound.
10.Optical fibers
11.Non Metallic Central Strength Member(FRP)

Optik Fiber Type SM : 652-B, G 652-D, G 655 MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3
Tensile Strength (N) (IEC 794-1-E1) 2500 (Min.) to 8000
Crush Strength (N/10 cm) (IEC 794-1-E3)

 

5000
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11) 15xo static &20xo dynamic where o is cable outside diameter in mm
Temperature Range (°C) (IEC 794-1-F -1) Operation -40 to + 70 Installation -30 to + 60

 

Fiber Count

Buffer Count Filler Count Inner and outer sheath thickness Cable Diameter Aprx Cable Weight (Kg/Km)

4

2

4

1.1/2

16

220

6

3

3

1.1/2

16

220

8

4

2

1.1/2

16

220

10

5

1

1.1/2

16

230

12

6

-

1.1/2

16

230

24

6

-

1.1/2

16

230

36

6

-

1.1/2

16

265

48

6

-

1.1/2

18

265

60

5

1

1.1/2

18

290

72

6

-

1.1/2

18

290

96

8

-

1.1/2

19,5

375

144

12

-

1.1/2

21,5

500

CABLE TYPE : MLT-SA-DJ-T.T.
APPLICATION : - Heavy duty cable for direct burial / duct usage.
- Suitable to be installed and used in harsh environments under heavy weather conditions
- Corrugated Steel Tape Armor, Second Jacket and Aluminum foil provides extra protection against moisture and all other external effects
- Suitable to be used for all type of underground applications
- Rodent Protection and waterproof
- Used as the principle backbone cable in Turkish Telecom main Network
CONSTRUCTION : 1.Outer PE Sheath. (Orange)
2.Corrugated Steel Tape Armored
3.Inner PE Sheath
4.Aramid yarn for tensile strength
5.Core Wrapping(s)
6.Core filling Compound.
7.Ripcord
8.PBT Tube
9.Water Resistive Tube filling Compound.
10.Optical fibers
11.Non Metallic Central Strength Member(FRP)

 

Optik Fiber Type SM : 652-B, G 652-D, G 655 MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3
Tensile Strength (N) (IEC 794-1-E1) 5000 (Min.) to 6000
Crush Strength (N/10 cm) (IEC 794-1-E3) 5000
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11) 15xo static &20xo dynamic where o is cable outside diameter in mm
Temperature Range (°C) (IEC 794-1-F -1)

 

Operation -40 to + 70 Installation -30 to + 60

 

Fiber Count

Buffer Count

 

Filler Count

Inner and outer sheath thickness

Cable Diameter Aprx

Cable Weight (Kg/Km)

4

2

4

1.1/2

16,5

240

6

3

3

1.1/2

16,5

240

8

4

2

1.1/2

16,5

240

10

5

1

1.1/2

16,5

250

12

6

-

1.1/2

16,5

250

24

6

-

1.1/2

16,5

250

36

6

-

1.1/2

16,5

285

48

6

-

1.1/2

18,5

285

60

5

1

1.1/2

18,5

310

72

6

-

1.1/2

18,5

310

96

8

-

1.1/2

20

400

144

12

-

1.1/2

22

550

CABLE TYPE : MLT-NMA-DJ / (A-DF(ZN)2YB2Y)
APPLICATION : - Light weight cable for direct burial / duct type.
- Light weight structure enables easy and fast installation
- Rodent Protection and waterproof
- To be used as backbone cable for MAN, WAN, LAN, applications and for GSM, CATV, SMATV networks
- Non Metallic Construction / All dielectric structure prevents electromagnetic interference and enables application in power lines side by side with Energy Cables
- Possibility of installation with blowing / plough technique into PE pipes
CONSTRUCTION : 1.Outer PE Sheath.
2.Non metallic strength member(Aramid Yarn or Glass Yarn)
3.Inner PE Sheath
4.Core Wrapping(s)
5.Core filling Compound.
6.PBT Tube
7.Optical fibres
8.Water Resistive Tube filling Compound
9.Non Metallic Central Strength Member (FRP)
10.Ripcord

 
Optik Fiber Type SM : 652-B, G 652-D, G 655 MM : 62.5/125 OM1, 50/125 OM2, 50/125 OM3
Tensile Strength (N) (IEC 794-1-E1) 2000 (Min.) to 5000
Crush Strength (N/10 cm) (IEC 794-1-E3)

 

4000
Min. Permissible Bending Radius (mm) (IEC 794-1-E 11)

 

15xo static &20xo dynamic where o is cable outside diameter in mm
Temperature Range (°C) (IEC 794-1-F -1)

 

Operation -40 to + 70 Installation -30 to + 60

 

Fiber Count

Buffer Count Filler Count Inner and outer sheath thickness Cable Diameter Aprx Cable Weight (Kg/Km)

4

1 5 1.1/1.6 14 140

6

1 5 1.1/1.6 14 140

8

2 4 1.1/1.6 14 140

10

5 1 1.1/1.6 14 140

12

3 3 1.1/1.6 14 140

24

6 - 1.1/1.6 14 140

36

6 - 1.1/1.6 14 140

48

6 - 1.1/1.6 14 140

60

5 1 1.1/1.6 16 180

72

6 - 1.1/1.6 16 180

96

8 - 1.1/1.6 18 230

144

12 - 1.1/1.6 20 390

 

© 2011 SIPTEL™ Tous droits réservés